SENECA Blog | Articoli, news e tips sulle tecnologie di automazione e interfaccia perm_identity
menu
search
  • www.seneca.it
  • expand_more Site Menu
    • ITALIANO
    • ENGLISH

Welcome! Please sign-in to your account. Thank you!


Electrical measurements, Energy monitoring, Instrumentation

Instrumentation for T&M

Increasingly smart, multifunctional and interconnected Test&Measurement instruments are fundamen …

Last updated26 August 202027 July 2020 by SENECA
Connection techniques, Data Acquisition, Signal conditioning

Signal Conditioning Guide – Part Two

In many factory and process automation applications the problem is to implement the conversion of on …

Last updated24 July 202024 July 2020 by SENECA
Connection techniques, Data Acquisition, Signal conditioning

Signal Conditioning Guide – Part One

Is it possible to avoid the deadlock of an industrial process? Yes, if galvanic isolation and signal …

Last updated24 July 202024 July 2020 by SENECA
Automation, Energy monitoring, Software

The SoftPLC concept

Since the late 1990s, the growth of the role of software in automation has accentuated the spread of …

Last updated1 July 202026 June 2020 by SENECA
Industrial Communication, IoT/Cloud

SENECA Cloud Computing solutions

Cloud Computing was born in the early ’60s of the twentieth century, when the U.S. computer sc …

Last updated26 June 202022 June 2020 by SENECA
Industrial Communication, IoT/Cloud, Remote Assistance, Remote control

Integration and connectivity with IoT Gateways

The IoT Gateway market is a complex and constantly evolving market with hundreds of technologies and …

Last updated29 May 202029 May 2020 by SENECA
Industrial Communication

What you need to know about the “ModBUS Pass-Through” function

The advanced “ModBUS Pass-Through” function allows ModBUS devices to divert requests fro …

Last updated20 May 202020 May 2020 by SENECA
Data Acquisition, Industrial Communication, Remote control

What is meant by datalogger

A datalogger is an automatic data acquisition system consisting of one or more electronic probes con …

Last updated21 May 202014 April 2020 by SENECA
Automation, Software

IEC 61131 and SoftPLC Straton

Evolution of IEC 1131 (published in 1992), IEC 61131 represents the most successful effort to standa …

Last updated21 May 202014 April 2020 by SENECA
Industrial Communication, Metering

M-BUS, the protocol for smart meters

Meter-Bus or M-Bus is a European standard (EN 13757-2 for the physical and connection level, EN 1375 …

Last updated21 May 202014 April 2020 by SENECA
Data Acquisition, Signal conditioning, Temperature Control

Thermocouples vs Thermoresistances: principles and applications

In industry context, temperature is one of the most frequently measured physical quantities. Some cr …

Last updated16 April 202014 April 2020 by SENECA
Electrical measurements, Instrumentation

The importance of Surge Protections

Surge Protective Devices (SPDs), commonly referred to as “surge arresters”, are designed …

Last updated16 April 202014 April 2020 by SENECA
Data Acquisition, HMI, Instrumentation

Benefits of OLED technology

OLED (Organic Light Emitting Diode) technology is based on a series of layers of organic material th …

Last updated16 April 202014 April 2020 by SENECA
Automation, Data Acquisition, Industrial Communication

OPC UA, the Industry 4.0 Standard

OPC UA (Open Platform Communications Unified Architecture) is an open communication protocol for ind …

Last updated16 April 202014 April 2020 by SENECA
Automation, Data Acquisition, Industrial Communication

CANopen technology

With about 2 billion chips with CAN controllers sold since 1989, the Italian market is the third lar …

Last updated16 April 202014 April 2020 by SENECA
Connection techniques

How to make a current loop

The realization of a current loop in an electrical or automation cabinet is essential to acquire sig …

Last updated16 April 20201 April 2020 by SENECA

Posts navigation

Older posts
Newer posts

Welcome to the SENECA blog

This blog is an important opportunity to share the corporate and technological know-how that SENECA, with over thirty years of experience in the main industrial sectors, has decided to make available to its customers, partners and professional operators.
We wish you good reading!
search

Recent Posts

  • The MID Directive for Energy Counters
  • Water treatment products and solutions
  • SENECA Solutions for Edge Computing
  • How to Choose Current Transducers
  • Flexibility and innovation for the electricity grids of the future, the case of Lombarda Motori
  • Remote control of water networks and Sustainability
  • Short Guide to UL Certification
  • When using Power Quality Meters
  • What is SNMP and what is it for?
  • Data Acquisition in Industry 4.0 era

Categories

  • Automation
  • Connection techniques
  • Data Acquisition
  • Electrical measurements
  • Energy monitoring
  • Industrial Communication
  • Instrumentation
  • Remote Assistance
  • Remote control
  • Signal conditioning
  • Temperature Control

Subscribe to our blog

You will always be updated on the latest articles that will be published



property of:
SENECA srl
Via Austria, 26
35127 Padova
T. 049 8705359 F. 0498706287
E. marketing@seneca.it, info@seneca.it
www.seneca.it

Categories

  • Automation
  • Connection techniques
  • Data Acquisition
  • Electrical measurements
  • Energy monitoring
  • Industrial Communication
  • Instrumentation
  • Remote Assistance
  • Remote control
  • Signal conditioning
  • Temperature Control

Archives

  • November 2022
  • October 2022
  • June 2022
  • March 2022
  • January 2022
  • October 2021
  • June 2021
  • May 2021
  • April 2021
  • March 2021
  • February 2021
  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • March 2020

Disclaimer

This blog is not a newspaper as it is updated without any periodicity. It cannot therefore be considered an editorial product according to the italian law n° 62 of 7.03.2001. Some of the images included in this blog are taken from the Internet and, therefore, considered public domain; if their publication violates any copyright, please communicate it by email. They will be removed immediately. The author of the blog is not responsible for the linked sites or their content, which may be subject to change over time.
© SENECA 2022. All Rights Reserved. È vietato copiare e riprodurre il contenuto (o parte di esso) in qualsiasi forma // It is forbidden to copy and reproduce the contents (or part of them) in any form.
Scroll to top vertical_align_top